Need clarification
Raj,
First of all it’s a NDA violation. You should not ask this type of Qs on the forum…..
Anyway get ready for 2nd attempt and as far as clarification is concern, I believe your Switching section is not up to CCIE level. Dig further and think logically to find out what was the mistake.
Regards __________________ Amir Tahir
—–Original Message—– From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of Angelo De Guzman Sent: Thursday, April 03, 2008 5:48 AM To: ccielab@groupstudy.com Subject: Re:Failed R&S 1st attempt: Need clarification
Looks like you’ll be having a lot of free time.
jai_in@hotmail.com (4/2/2008 11:09 PM): >Hi guys, > >unfortunately…i failed in my first attempt, as i was not ale to establish the >connection between one Backbone and a Lab router…..apart from this everything >went well. > >all IGP/ BGP connection / negihborship worked but was not able to make the >eigrp working between BBX and a router. > >Router X is connected to fa0/6 of sw2 and Backbone is connected to fa0/10 of >sw3 > >etherchannel/trunk between sw1—sw2—sw3—-sw4 …..sw1 vtp >server….sw2-3-4 client with same domain… > >made port fa0/6 of sw2 and fa0/10 of sw3 acesss port for same vlan… >but didn’t get any routes from BB when running eigrp…. > >seems to be silly mistake…but wana clarify this to gear up for 2nd and final >attemt
>thx… > >Raj > >_______________________________________________________________________ >Subscription information may be found at: >http://www.groupstudy.com/list/CCIELab.html