DE Marking with MIN CIR
The legacy method, by the way is the de-group/de-list commands.
—–Original Message—– From: nobody@groupstudy.com [mailto:nobody@groupstudy.com] On Behalf Of shank shank Sent: Sunday, November 30, 2008 5:18 PM To: CCIE Group Subject: DE Marking with MIN CIR
hello experts, i was working on some labs with fram realy taks and i came across a task that asks for setting the DE bit. the solution was through MQC but i was wondering isn’t that done by default when we use the Cir and the mincir command in the frame relay traffic shaping. i’m just thinking of an alternative solution. can anybody confirm to me if it could be done any other way than MQC?
Blogs and organic groups at http://www.ccie.net